12
INSTALLATION
NOTE
• For closet installation, with a door, minimum
ventilation openings in the top and bottom of
the door are required. Louvered doors with
equivalent ventilation openings are acceptable.
• Minimum vent opening for built-in installation is
31.5 sq. in. (200 cm
2
.)
Closet Ventilation Requirements
Closets with doors must have both an upper and
lower vent to prevent heat and moisture build-up
in the closet.
One example shown uses vent grilles in the door.
a
Upper vent opening with a minimum opening
of
48 sq. in. (310 cm
2
)
must be installed no
lower than
6 ft. (185 cm)
above the floor.
b
Lower vent opening with a minimum opening
of
24 sq. in. (155 cm
2
)
must be installed no
more than one foot above the floor.
Ambient Temperature
• Temperature must be between
50
℉
(10 °C)
and
95
℉
(35 °C)
.
• If the ambient temperature is too low or high,
performance may be affected.
• Do not install in direct sunlight or where the
temperature may fall below
32
℉
(0 °C)
.
Electrical Connection
• Do not use an extension cord or 2-outlet
adapter.
• Do not overload the outlet with more than one
appliance.
• Connect the appliance to an earthed socket in
accordance with current wiring regulations.
• The appliance must be positioned close to
outlets and the plug should be easily accessible.
WARNING
• The power cord must be plugged into an
appropriate outlet that is installed and
grounded/earthed in accordance with all local
codes and ordinances.
Dimensions
inch
mm
A
25 1/2
650 mm
B
2
18
2
455 mm
C
2
10
2
250
D
2
74 3/8
2
1889
E
2
74 1/8
2
1875
F
2
15 3/4
2
400
G
2
2
2
50
H
2
24 7/8
2
630
I
2
19
2
485
J
2
2
2
50
K
2
1
2
25
L
2
1 3/16
2
30
B
I
H
E
D
F
G
J
K
L
L
7.6 cm
7.6 cm
7.6 cm
7.6 cm