HOW TO USE
15
ENGLISH
Auto Clean
This function dries inside of the dehumidifer in order to prevent mold or germs.
- Press the operation mode button for about 3 seconds during operation to set up Auto Clean.
- Each time the operation mode button is pressed for 3 seconds: Auto Clean → settings cancella-
tion - then it repeats
- When running Auto Clean a
is displayed on the display.
- After Auto Clean function finishes, the LED display automatically turns off.
- When the operation stops, the Auto Clean will start.
When Auto Clean function starts, the dehumidifier will run the fan for a certain period in order to
remove moisture inside the product. (Duration: about 5 minutes)
Defrost Operation
If there is frost in the heat exchanger due to low indoor temperature, it automatically re-
moves the frost.
- During the operation, if ‘dF’ is displayed on the display, it automatically runs the defrost in the
heat exchanger inside the product.
- Compressor is stopped during the automatic defrost operation.
Ionizer
When you want to remove harmful bacteria in the air
- Select it by pressing Ionizer button.
- It removes harmful material in the air such as bacteria, virus, etc. using ionized air.
- You can use Ionizer function and dehumidification function at the same time.
- Ionizer can be used at any time regardless of dehumidifier function.