5-19
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1. Setting time
does not count
down when
touching START
pad.
2. Fan motor or
oven lamp do
not turn on.
No continuity.
Continuity.
Continuity
Defective PCB
assembly.
Loose connection.
Replace PCB
assembly.
Connect them
tightly.
No continuity
Abnormal
Check fan motor.
Defective fan motor.
Replace fan motor.
Abnormal
Normal
Check oven lamp.
Defective oven lamp.
Replace oven lamp.
Defective
secondary switch.
Replace
secondary switch.
Check continuity
of secondary
switch (with
door closed).
Check the con-
nection between
CN1 connector
and PCB
assembly.
(TROUBLE 3) Display shows all figures set, but microwave oven does not start cooking while desired
program times are set and START pad is touched.
(TROUBLE 4) Microwave oven seems to be operating but little heat is produced in oven load.
NOTE : Simple test of power output-conducted by heating one liter water for one min. if available.
Minimum 8.5°C temperature rise is normal condition.
CONDITION
CHECK
RESULT
CAUSE
REMEDY
Output is low
Lower than 90% of
rating voltage.
Normal
Abnormal
Defective PCB
assembly.
Replace PCB
assembly.
Normal
Abnormal
Measure the
output power.
Defective
magnetron.
Replace
magnetron.
Decrease in power
source voltage
with load.
Suggest customer
contact local
electric power
utility co. or
qualified
electrician.
Check the
power source
voltage.
Disconnect the
wire leads from
relay 2 and
check on and off
time with
multitester.
Summary of Contents for MD-2642KT
Page 34: ...6 3 WTP004 268712 23506A CONTROLLER PARTS ...
Page 35: ...6 4 WTP013 35889A 34370T 36549S 33390G WTT010 WTT021 33052A 33112U OVEN CAVITY PARTS ...
Page 36: ...6 5 WSZ085 56912B 55262A 44510A 43500A 466001 466003 466001 43501A LATCH BOARD PARTS ...
Page 38: ...6 7 56170D 63303A WSZ002 WTT021 WTT028 647781 65006A 63302A WTT021 BASE PLATE PARTS ...
Page 41: ...8 2 MAIN PRINTED CIRCUIT BOARD ...
Page 42: ...8 3 KEY PRINTED CIRCUIT BOARD ...
Page 43: ...P NO 3828W5S3131 April 2003 Printed in Korea ...