C. DOOR GROSS ASSEMBLY
REMOVAL
(1) Open the door.
(2) Remove the choke cover cap very carefully with a flat-
blade screwdriver.
CAUTION : Be careful not to damage door seal plate
by screwdriver.
(3) Lift up and push the door.
NOTE:
1. After replacing the door, be sure to check that the
primary switch, monitor switch, and secondary switch
operate normally.
2. After replacing the door, check for microwave energy
leakage with a survey meter. Microwave energy must
be below the limit of 5 mW/cm.sq. (with a 275 ml water
load)
3. When mounting the door assembly to the oven
assembly, be sure to adjust the door assembly parallel
to the chassis. Also adjust so the door has no play
between the inner door surface and oven frame
assembly. If the door assembly is not mounted
properly, microwaves may leak from the clearance
between the door and the oven.
5-5
Remove choke cover cap
Remove Door
Figure 9
Summary of Contents for MD-2642KT