18 Room Air Conditioner
Disassembly
Refrigeration cycle
CAUTION: Discharge the refrigerant system using Freon
TM
Recovery System.If
there is no valve to attach the recovery system, install one (such as a WATCO A-1)
before venting the Freon
TM
. Leave the valve in place after servicing the system.
16. CONDENSER
1. Remove the cabinet. (Refer to section 2)
2. Remove the brace and the shroud cover.
(Refer to section 4)
3. Remove 2 screws which fasten the side cover.(See Fig. 33)
4. Remove the 5 or 6 screws which fasten the condenser.
5. After discharging the refrigerant completely, unbraze the
interconnecting tube at the condenser connections.
6. Remove the condenser.
7. Re-install the components by referring to notes.
(See Fig. 33)
17. EVAPORATOR
1. Remove the cabinet. (Refer to section 2)
2. Remove the top cover and the brace.
(Refer to section 4)
3. Discharge the refrigerant completely.
4. Remove the 3 screws which fasten the evaporator at the
left side and the top side.
5. Move the evaporator sideward carefully and then unbraze
the interconnecting tube at the evaporator connectors.
6. Remove the evaporator.
7. Re-install the components by referring to notes.
(See Fig. 34)
18. CAPILLARY TUBE
1. Remove the cabinet. (Refer to section 2)
2. Remove the brace. (Refer to section 4)
3. After discharging the refrigerant completely, unbraze the
interconnecting tube at the capillary tube.
4. Remove the capillary tube.
5. Re-install the components by referring to notes.
Figure 33
Figure 34
Therm
ostat
Operatio
n
Wait Three
Minutes
Before Re
starting
Cooler
Warmer
Off
Auto Sw
ing
Off
On
Fan
Fan
Low Hea
t
Low Coo
l
High Cool
High H
eat
Summary of Contents for M2400HR
Page 35: ...Service Manual 35 Memo ...