16
Installation
3
Ins
talla
tion
Connecting LKD1000 controller
1. Connect the RJ-45 Adapter cable to the PORT A (RJ-45)
cable of the camera.
2. Connect the LKD1000 controller to the RJ-45 Adapter
cable. (Refer to the manuals of the LKD1000 controller
for more details.)
LKD1000 connection
E
D
C
B
A
G
F
H
PORT A
TX-
TX+
RJ-45 Adapter cable
E
D
C
B
A
G
F
H
PORT A
RJ-45 Adapter cable
RS-485 device
RJ-45 Adapter cable
Port A
RJ-45 Adapter cable
No
Description
Color
A
RS-485 +
White
B
RS-485 -
Orange
Connecting RS-485 device
Use the cable that is described below for RS-485 site
communication.
• Shielded, twisted pair cable
• Low impedance
• Wire gauge size is thicker than AWG #22 (0.33 mm
2
).
RS-485 connection
E
D
C
B
A
G
F
H
PORT A
TX-
TX+
RJ-45 Adapter cable
E
D
C
B
A
G
F
H
PORT A
RJ-45 Adapter cable
RS-485 device
RJ-45 Adapter cable
RS-485 device
Port A
1. Connect the RJ-45 adapter cable to the PORT A (RJ-45)
cable of the camera.
2. Connect the RS-485 device to the RJ-45 Adapter cable.
When connecting lines, connect the “Orange color line”
of the RJ-45 Adapter cable to “RX -” of the RS-485 unit
and “White color line” of the RJ-45 Adapter cable to “RX
+” of the RS-485 unit correctly.
RJ-45 Adapter cable
No
Description
Color
A
RS-485 +
White
B
RS-485 -
Orange
PORT A of the LT913/713NI/PI series
Description
Color
RS-485 +
Red/White
RS-485 -
Black/White
PORT A of the LT913/713N/P series
Description
Color
RS-485 +
Green
RS-485 -
Blue