INSTALLATION
ENGLISH
9
Outdoor unit
- If an awning is built over the unit to prevent
direct sunlight or rain exposure, be careful
that heat radiation from the condenser is not
restricted.
- There should not be any animals or plants
which could be affected by hot air dis-
charged.
- Ensure the spaces indicated by arrows from
the wall, ceiling, fence or other obstacles.
Place with fluent water draining
- Install at a place with fluent water draining to
prevent damage from localized heavy rain
and avoid frequent flooded area.
Unit:mm
Ceiling
Ceiling
B
oard
Ceiling
B
oard
Abo
ve
2500
3
600 or les
s
1000
or mor
e
1500 or
more
1500 or
more
3
00 or les
s
Floor
200 or more
More than
3
00
More than 700
More than 600
More than
More than
300
300
Sunroof
Fence or
obstacles
OUTDOOR
OU
TD
OO
R
Unit
Unit
OUTDOOR
Unit
More than
3
00
Unit : mm
Installation of Indoor, Outdoor
Unit
Selection of the best location
Indoor unit
- There should not be any heat source or
steam near the unit.
- There should not be any obstacles to prevent
the air circulation.
- A place where air circulation in the room will
be good.
- A place where drainage can be easily
obtained.
- A place where noise prevention is taken into
consideration.
- Do not install the unit near the door way.
- Ensure the spaces indicated by arrows from
the wall, ceiling, or other obstacles.
- The indoor unit must keep the maintenance
space.
* Please use an annexed sheet or the corru-
gated cardboard on the bottom of packing
as installation sheet.
• When using the bottom sheet, please use it
after separating the installation sheet from
packing of the product floor by using a knife
etc as a picture below.
Annexed sheet
Or
Packing corrugated
cardboard on the
bottom