34
TROUBLESHOOTING
(1) To (2)
Result
38
30
24
19.5
16
23
/ -5
32
/ 0
41
/ 5
50
/ 10
59
/ 15
No
Result & SVC Action
<Temperature table-2>
Checking flow
Short
Open
Normal
Change the sensor
Replace the refrigerator
Check the Temp and
resistance(Table-2)
SVC Action
0
OFF
Other
Result
1
2
Check the Pin9(1) to Pin10(2) of CON6.
The sensor is determined by the
temperature.
For example, 30
indicates 0
CON 6
Check for a loose connection.
2. Troubleshooting With Error Display
3) Refrigerator Sensor Error(Er r2)