Oven shows error
code (F9, F19) but
cooktop burners
are working.
The gas pressure regulator valve is closed.
a
Lever’s closed position
• Check that the regulator valve is in the open position.
• If the regulator valve is closed, rotate the lever to open the valve.
a
Lever’s closed position
c
Lever’s open position
Flames too big on
converted cooktop
(NP
~
LP)
The installer missed part of the conversion. (Check 3 parts: regulator, cooktop
valve, broil/bake valve.)
a
Regulator
b
Cooktop valve
c
Broil/Bake valve
• Check with installer first.
• Refer to installation manual.
Flame is too small
or too large
1. Variable gas pressure
2. Installer did not check
• Check with installer first.