background image

15

INSTALLATION

ENGLISH

Dimensions and Clearances

Provide proper clearance between the range and adjacent combustible surfaces. These dimensions must be met 
for safe use of your range. The location of the electrical outlet and pipe opening (see Gas Pipe and Electrical 
Outlet Locations, page 14) may be adjusted to meet specific requirements. The range may be placed with 0" 
clearance (flush) at the back wall.

Installation Clearances

30"

(76.2 cm)

30" (76.2 cm)

Minimum

15"

(38.1 cm)

36"

(91.4 cm)

13" 

(33.0 cm)

Maximum 

depth for 

cabinets above 

coutertops

Front edge of 

the range side 

panel forward 

from cabinet

0"

To cabinets 

below 

cooktop and 

at the range 

back

1

/

4

"

Dimensions

28 

3

/

4

(73.0 cm)

Height

37 

59

/

64

(96.3 cm)

Depth with door open 

43 

5

/

32

" (109.6 cm)

Depth with door closed 

(includes door handle)

36" 

(91.4 cm)

29 

7

/

8

"

(75.7 cm)

Summary of Contents for LSG4513BD

Page 1: ...as connector it must not exceed 3 feet in length Preparing for Installation Tools needed Phillips screwdriver Open end or adjustable wrench Pencil and ruler Level Flat blade screwdriver Pipe wrench 2 one for support Materials You May need Gas line shut off valve Pipe joint sealant that resists action of natural and LP gases Flexible metal appliance connector 3 4 or 1 2 NPT x 1 2 I D Never use an o...

Page 2: ...ing the Proper Location Do not locate your range where it may be subject to strong drafts Any openings in the floor or wall behind the range should be sealed Make sure the openings around the base of the range that supply fresh air for combustion and ventilation are not blocked by carpeting or woodwork Your range like many other household units is heavy and can be installed on soft floor coverings...

Page 3: ...djusted to meet specific requirements The range may be placed with 0 clearance flush at the back wall Installation Clearances 30 76 2 cm 30 76 2 cm Minimum 15 38 1 cm 36 91 4 cm 13 33 0 cm Maximum depth for cabinets above coutertops Front edge of the range side panel forward from cabinet 0 To cabinets below cooktop and at the range back 1 4 Dimensions 28 3 4 73 0 cm Height 37 59 64 96 3 cm Depth w...

Page 4: ...idge the opening at the rear wall the rear filler kit that is provided with the slide in range will be needed nOTE If the countertop depth is greater than 25 there will be a gap between the filler kit and the back wall If the countertop depth is less than 24 the control panel will not sit flush with the countertop Installing the rear Filler 1 Using a screwdriver remove the upper four screws that a...

Page 5: ...tion nOTE The gas pressure regulator valve is open when shipped If the range does not work properly after installation make sure the regulator valve is still open 3 Connect a flexible metal appliance connector to the adapter on the range Position the range to permit connection at the shut off valve 4 When all connections have been made be sure all range controls are in the OFF position and the pre...

Page 6: ...h off power when a threshold leakage level is detected These devices must be manually reset by the consumer The National Electrical Code requires the use of GFCI s in kitchen receptacles installed to serve countertop surfaces Performance of the range will not be affected if operated on a GFCI protected circuit but the occasional resetting of the circuit can become an annoyance Ensure proper ground...

Page 7: ...ld ignite within 4 seconds After the burner ignites rotate the knob out of the Lite position Try each burner in succession until all burners have been checked Quality of Flames The combustion quality of the burner flames needs to be confirmed visually A Yellow flames Call for service B Yellow tips on outer cones This is normal for LP gas C Soft blue flames This is normal for natural gas nOTE With ...

Page 8: ...ersions The range comes from the factory with the air shutters adjusted for proper air flow for natural gas If converted to LP follow the instructions provided in the conversion kit to properly adjust the air shutters LP conversion must be performed by a qualified technician Leveling the range Level the range by adjusting the leveling legs Extending the legs slightly may also make it easier to ins...