INSTALLATION

ENGLISH

Connecting the range to Gas

Shut off the range gas supply valve before removing 
the old range and leave it off until the new hook-up 
has been completed.
Because hard piping restricts movement of the range, 
the use of a CSA International-certified flexible metal 
appliance connector should be used unless local 
codes require a hard-piped connection.
A manual valve shall be installed in an accessible 
location in the gas piping external to the appliance 
for the purpose of turning on or shutting off gas to the 
appliance.
Never reuse an old connector when installing a new 
range.
To protect against gas leaks, use a qualified pipe joint 
sealant on all external threads.

1

Install a male 

1

/

2

" or 

3

/

4

" flare union adapter to the 

NPT internal thread of the manual shut-off valve, 
taking care to back-up the shut-off valve to keep 
it from turning.

2

Install a male 

1

/

2

" flare union adapter to the 

1

/

2

NPT internal thread at the inlet of the pressure 
regulator. Use a backup wrench on the pressure 
regulator fitting to prevent damage.

Check that the gas pressure regulator valve is in the 
open position. 

Lever’s open 

position

Lever’s closed 

position

nOTE

 

The gas pressure regulator valve is open when 
shipped. If the range does not work properly 
after installation, make sure the regulator valve 
is still open.

3

Connect a flexible metal appliance connector to 
the adapter on the range. Position the range to 
permit connection at the shut-off valve.

4

When all connections have been made, be sure

 

all range controls are in the OFF position and the

 

pressure regulator valve is open before turning 
on

 

the main gas supply valve. Gas leaks may 

occur in

 

your system and create a hazard. Gas 

leaks may not

 

be detected by smell alone.

Check all gas connection joints and fittings for 
leaks with a non-corrosive leak detection fluid, 
then wipe off.
Gas suppliers recommend you purchase and 
install a UL approved gas detector. Install 
and use in accordance with the installation 
instructions.

WArnInG

 

Do not use a flame to check for gas leaks.

 

Isolate the range from the gas supply system 
by closing its individual shut-off valve during 
any pressure testing of the gas supply system 
at test pressures equal to or less than 

1

/

2

" psig 

(3.5 kPa).

Flexible Connector Hookup

1

/

2

Adapter

1

/

2

Adapter

Pressure regulator

Flex connector
(6 ft. max.)

Adapter

Gas shut-off 
valve

1

/

2

" or 

3

/

4

" Gas 

pipe

Gas Flow into Range

Installer: Inform the consumer of the location of the gas 
shut-off valve

.

Pressure regulator Position 

Pressure Regulator

Summary of Contents for LSG4513BD

Page 1: ...as connector it must not exceed 3 feet in length Preparing for Installation Tools needed Phillips screwdriver Open end or adjustable wrench Pencil and ruler Level Flat blade screwdriver Pipe wrench 2 one for support Materials You May need Gas line shut off valve Pipe joint sealant that resists action of natural and LP gases Flexible metal appliance connector 3 4 or 1 2 NPT x 1 2 I D Never use an o...

Page 2: ...ing the Proper Location Do not locate your range where it may be subject to strong drafts Any openings in the floor or wall behind the range should be sealed Make sure the openings around the base of the range that supply fresh air for combustion and ventilation are not blocked by carpeting or woodwork Your range like many other household units is heavy and can be installed on soft floor coverings...

Page 3: ...djusted to meet specific requirements The range may be placed with 0 clearance flush at the back wall Installation Clearances 30 76 2 cm 30 76 2 cm Minimum 15 38 1 cm 36 91 4 cm 13 33 0 cm Maximum depth for cabinets above coutertops Front edge of the range side panel forward from cabinet 0 To cabinets below cooktop and at the range back 1 4 Dimensions 28 3 4 73 0 cm Height 37 59 64 96 3 cm Depth w...

Page 4: ...idge the opening at the rear wall the rear filler kit that is provided with the slide in range will be needed nOTE If the countertop depth is greater than 25 there will be a gap between the filler kit and the back wall If the countertop depth is less than 24 the control panel will not sit flush with the countertop Installing the rear Filler 1 Using a screwdriver remove the upper four screws that a...

Page 5: ...tion nOTE The gas pressure regulator valve is open when shipped If the range does not work properly after installation make sure the regulator valve is still open 3 Connect a flexible metal appliance connector to the adapter on the range Position the range to permit connection at the shut off valve 4 When all connections have been made be sure all range controls are in the OFF position and the pre...

Page 6: ...h off power when a threshold leakage level is detected These devices must be manually reset by the consumer The National Electrical Code requires the use of GFCI s in kitchen receptacles installed to serve countertop surfaces Performance of the range will not be affected if operated on a GFCI protected circuit but the occasional resetting of the circuit can become an annoyance Ensure proper ground...

Page 7: ...ld ignite within 4 seconds After the burner ignites rotate the knob out of the Lite position Try each burner in succession until all burners have been checked Quality of Flames The combustion quality of the burner flames needs to be confirmed visually A Yellow flames Call for service B Yellow tips on outer cones This is normal for LP gas C Soft blue flames This is normal for natural gas nOTE With ...

Page 8: ...ersions The range comes from the factory with the air shutters adjusted for proper air flow for natural gas If converted to LP follow the instructions provided in the conversion kit to properly adjust the air shutters LP conversion must be performed by a qualified technician Leveling the range Level the range by adjusting the leveling legs Extending the legs slightly may also make it easier to ins...

Reviews: