7. Heating Mode Operation
The unit will operate according to the setting by the remote controller and the operation diagram is shown as
following.
8. Hot-Start Control
ƒU
The indoor fan stops until the evaporator piping temperature will be reached at 28
¡
. (BY TEMPERATURE)
ƒU
The operation diagram is as following.
ƒ¡
18
ƒ¡
Intake Air temp.
Setting temp.+3
¡
(Compressor OFF)
Setting temp.
(Compressor ON)
INDOOR FAN
Low
OFF Low
Low
OFF
COMPRESSOR
ON
OFF
ON
OFF
ƒU
A point; The indoor pipe temperature to be 35°C
The indoor fan operates minimum 10sec. even if falls lower than 35°C
ƒU
B point; The indoor pipe temperature to be 35°C
The indoor fan operates minimum 10sec. even if falls lower than 35°C
Selecting fan
speed
HOT
START
OFF
Selecting fan
speed
minimum
10sec.
A
A
minimum
10sec.
minimum
10sec.
B
¢”
¢”
PIPING
TEMP 28°C
60 sec.
COMPRESSOR
INDOOR
FAN
LOW
OFF
SELECTING
FAN SPEED
ON
(HOT-START BY TEMPERATURE)