ƒ¡
32
ƒ¡
3. Insert the connecting cables, the drain pipe
and connecting pipings throught the piping
hole on the wall.
4. Connect connecting pipings and indoor tubing,
and the drain hose and the drain pipe and
place the drain pipe into the chassis.
• Don't connect the cableto the indoor unit.
• Make a small loop for easy connection later.
• Glue up the connection portion of drain hose and
drain pipe.
5. Bend the drain hose as shown in the figure and
bind the drain hose, the pipings and the con-
necting cables altogether.
Outdoor
Indoor
Connecting Cable
Drain Pipe
Drain Hose
Connecting Piping
Loop
For left rear pipings
Pipe Size
Torque
Liquid Side (1/4")
1.8kg·m
Gas Side (3/8")
4.2kg·m
Indoor unit tubing
Flare nut Pipings
Torque wrench
Spanner
Drain Pipe
Drain Hose
Adhevsive