Note1) Freezer room notch temperature display and refrigerator room notch temperature display(Failure code indication
part) are normally indicated in abnormal ambient sensor, and “Er” indicated on the amvient temperature
display(except for the ambient temperature display, other LCDs are indicated normally)
Note2) R2-sensor, Ice-maker sensor miracle zone sensor and Ice-maker kit is not indicated on the failure indicating part but
indicated in checking LCD(When pressing for more than the button of freezing temperature and super freezer button
for more than 1 second).
R2-sensor(middle room)
Normal: LCD graphic on the (C) part turns on
Abnormal: LCD graphic on the (C) part turns off
Ice-making sensor
Normal: LCD graphic on the (D) part turns on
Abnormal: LCD graphic on the (D) part turns off
Ice-maker unit
Normal: LCD graphic on the (E) part turns on
Abnormal : LCD graphic on the (E) part turns off
Miracle zone sensor
Normal: LCD graphic on the (F) part turns on
Abnormal : LCD graphic on the (F) part turns off
2-17. Test Function
1. The purpose of test function is to check function of the PWB and product and to search for the failure part at the failure
status.
2. Test button is placed on the main PCB of refrigerator (test switch), and the test mode will be finished after maximum 2
hours irrespective of test mode and then is reset to the normal status.
3. Function adjustment button is not perceived during performance of test mode.
4. In finishing test mode, always pull the power cord out and then plug-in it again for the normal state.
5. If nonconforming contents such as sensor failure are found during performance of test mode, release the test mode and
display the failure code.
6. Even if pressing the test button during failure code display, test mode will not be performed.
MICOM FUNCTION
- 32 -
The other LCD Graphics Turn On.
Test 1
Test 2
Normal
Status
Mode
Operation
Contents
Remarks
Press test button once
(strong cold mode)
Press test button once at
the test mode 1 status
(forced defrost mode)
Press test button once at
the test mode 2 status
1. Continuous operation of compressor
2. Continuous operation of freezing bldc motor
(high-speed RPM) and cooling bldc motor
3. Defrost heater turns off
4. Stepping motor damper is completely
opened (open of baffle)
5. Miracle zone stepping motor damper is
completely closed.
6. All display LCD graphics turns on.
1. Compressor OFF
2. Freezing bldc motor and cooling bldc motor
turn off
3. Defrost heater turns on
4. Stepping motor damper is completely
closed (closing of baffle)
5. Miracle zone stepping motor damper is
completely closed.
6. All display LCD graphics turns off (only LCD
turns on for(A) “MIDIUM” status, (B)
“MIDIUM” status)
Return to the initial status.
Freezing fan turns off in
door opening
Return to the normal mode
when the defrost sensor is
above +5°C
Compressor will operate
after delay for 7 minutes
Summary of Contents for LRSC21934SW
Page 45: ...2 GR C247 B247 C207 B207 EXPLATION FOR MICOM CIRCUIT 45 ...
Page 54: ...2 GR C247 B247 C207 B207 EXPLATION FOR MICOM CIRCUIT 54 ...
Page 55: ...3 2 Parts list 1 GR P247 L247 P207 L207 EXPLATION FOR MICOM CIRCUIT 55 ...
Page 56: ...EXPLATION FOR MICOM CIRCUIT 56 ...
Page 57: ...2 GR C247 B247 C207 B207 EXPLATION FOR MICOM CIRCUIT 57 ...
Page 58: ...EXPLATION FOR MICOM CIRCUIT 58 ...
Page 59: ...3 3 DISPLAY ASSEMBLY part diagram 1 GR P247 L247 P207 L207 EXPLATION FOR MICOM CIRCUIT 59 ...
Page 60: ...2 GR C247 B247 C207 B207 EXPLATION FOR MICOM CIRCUIT 60 ...
Page 61: ...3 4 DISPLAY circuit diagram 1 GR P247 L247 P207 L207 61 Parts without mark means SMD parts ...
Page 62: ...2 GR C247 B247 C207 B207 62 Parts without mark means SMD parts ...
Page 64: ...EXPLATION FOR MICOM CIRCUIT 64 PCB ASSEMBLY DISPLAY PCB ASSEMBLY MAGIC DISPLAY ...
Page 65: ...2 GR C247 B247 C207 B207 EXPLATION FOR MICOM CIRCUIT 65 ...
Page 66: ...EXPLATION FOR MICOM CIRCUIT 66 PCB ASSEMBLY DISPLAY PCB ASSEMBLY MAGIC DISPLAY ...
Page 73: ...CIRCUIT 73 3854JD1103A ...
Page 74: ...CIRCUIT 74 3854JD1103A ...