Installation of Unit
Installation Manual 13
Connecting the Cable to Indoor Unit
• In order to protect cable, it should be inserted “Bushing Rubber”.
• The inside and outside connecting cable can be connected after opening the inlet grille.
1. Open the inlet grille manually.
2. Open the control cover with Driver(
⊕
⊕
).
3. Connect the supplied cables to the connector in the control box. (LP-Z808FA0)
4. Connect the supplied cables to the connector in the control box. (LP-H808FA0)
5. Connect the supplied cables to the connector in the control box. (LP-C80*F*0,LP-C100*F*0)
Where, *=8, 9, B *=A, E
Terminals on the indoor unit
CONNECT TO CONTACT "T", "N", OF
OUTDOOR TERMINAL BLOCK
MAGNETIC
SWITCH
1
2
3
4
5
6
Terminals on the outdoor unit
Housing ASM
(Connect to Outdoor)
BR
BR
BL
BL
GN/YL
POWER INPUT
3P4W 380~415V Heater Power
POWER INPUT
3P4W 380~415V
1(L) 2(N) 3
4
1
2
3
R
S
T
N
6
5
4
5
6
Main Terminal on the outdoor unit
R
S
T
N
Terminals on the indoor unit
CONNECT TO CONTACT "T", "N", OF
OUTDOOR TERMINAL BLOCK
1
2
3
4
5
6
Terminals on the outdoor unit
Housing ASM
(Connect to Outdoor)
BR
BR
BL
BL
GN/YL
POWER INPUT
3P4W 380~415V
1(L) 2(N) 3
4
1
2
3
6
5
4
5
6
R
S
T
N
Main Terminal on the outdoor unit
Terminals on the indoor unit
CONNECT TO CONTACT "T", "N", OF
OUTDOOR TERMINAL BLOCK
1
2
3
4
5
6
Terminals on the outdoor unit
Housing ASM
(Connect to Outdoor)
BR
BK
BL
GN/YL
POWER INPUT
3P4W 380~415V
1
2
3
4
1
2
3
4
5
6
R
S
T
N
Main Terminal on the outdoor unit
Summary of Contents for LPUC808FA0