3-16 CAP DUCT MOTOR REPLACEMENT
1) Separate the Housing of the Cap Duct Motor.
3) When replacing the motor, check the position of the door
duct and the link for proper fit.
Link
Duct Door
Cap Duct Motor
NG Position
2) Unscrew 3 screws to disassemble the motor.
4) Insert 2 screws.
5) Push housing aside.
3-15 SUB PWB FOR WORKING DISPENSER
1) Disconnect the wire harness.
2) Remove 1 screw from PWB and replace with new PWB.
CAUTION:
Make sure that the motor housing is taped to
the mold, if not positioned correctly the cover will not fit
properly.