Symptom
Check Point
1. F dS
1. Check for a loose connection
2. Check Sensor Resistance
Resistance [
Ω]
CON7
17
th
pin ~ 18
h
pin
Short
0
Open
OFF
Other
Normal
8-4. Defrost Sensor Error (F dS)
CON7
17
th
pin ~ 18
th
pin
Resistance [
Ω]
23ºF / -5ºC
38k
32ºF / 0ºC
30k
41ºF / 5ºC
24k
50ºF / 10ºC
19.5k
59ºF / 15ºC
16k
CON1
CON201
CON4
CON5
CON6
CON7
CON2
CON3
- 3
0
-