Symptom
Check Point
1. E IS
1. Check for a loose connection
2. Check Sensor Resistance
Resistance [
Ω]
CON5
15
th
pin ~ 17
th
pin
Short
0
Open
OFF
Other
Normal
8-3. Icing Sensor Error (E IS)
CON5
15
th
pin ~ 17
th
pin
Resistance [
Ω]
-22ºF / -30ºC
40k
-13ºF / -25ºC
30k
-4ºF / -20ºC
23k
-13ºF / -25ºC
17k
14ºF / -10ºC
13k
23ºF / -5ºC
10k
32ºF / 0ºC
8k
CON1
CON201
CON4
CON5
CON6
CON7
CON2
CON3
-
28
-
Summary of Contents for LMXS27626S
Page 4: ... 4 ...
Page 5: ...Top Drawer Bottom Drawer 5 ...
Page 20: ...5 CIRCUIT DIAGRAM 5 ...
Page 23: ... P N EBR60070711 33 7 PCB Picture 7 3 Sub PCB 23 ...
Page 73: ... 73 10 COMPONENT TESTING INFORMATION 10 1 ...
Page 106: ...600A 630F 630B 630A 630H 630G 630C 630Q 630E 630D 611A 612A 630J 606A 630J 607A ...
Page 107: ......