-31-
COMPONENTS
TEST
RESULTS
Normal:
Momentarily Infinite and
then soon reach 10 mega.
ohms
Normal: Infinite.
Normal:Infinite.
Abnormal: Below 100 ohms
Normal:Infinite.
Abnormal: Below 100 ohms
1. Remove wire leads.
2. Measure resistance. (ohm meter scale: Rx1000)
• Terminal to terminal
• Terminal to case
1. Measure continuity. Forward.
(ohm meter scale: Rx1000)
2. Measure continuity. Reverse.
(ohm meter scale: Rx1000)
CAPACITOR
DIODE
Some inexpensive ohm
meters may indicate infinite
resistance in both directions.
1. Measure continuity.
(ohm meter scale: Rx1)
2. Remove the lead wires and operate oven at
power level 1 through power level 10.
RELAY 2
1. Remove lead wires.
2. Measure resistance. (ohm meter scale: Rx1)
High speed : Blue and Black wire
Low speed : Blue and White wire
Slow speed : Blue and Grey wire
Normal:
High speed: Approximately
60 to 75 ohm
Low speed: Approximately
110 to 125 ohm
Slow speed: Approximately
65 to 85 ohm
VENTILATION MOTOR
Power
Level Open Close
1
2
3
4
5
6
7
8
9
10
4 Sec
6 Sec
8 Sec
10 Sec
12 Sec
14 Sec
16 Sec
18 Sec
20 Sec
22 Sec
18 Sec
16 Sec
14 Sec
12 Sec
10 Sec
8 Sec
6 Sec
4 Sec
2 Sec
0 Sec
Summary of Contents for LMV1762SB
Page 7: ... 7 4 OPERATION 4 1 Control Panel 12 14 15 17 23 20 16 21 22 19 13 2 3 1 6 7 9 11 8 10 4 5 18 ...
Page 10: ... 10 5 2 Key Matrix KEY MATRIX KEY MATRIX ...
Page 14: ... 14 6 4 Troubleshooting No Display or Dead ...
Page 16: ... 16 Keypad Failure ...
Page 44: ...W102 4000 4002 4003 4001 4004 4002 LATCH BOARD PARTS EV ...
Page 48: ......