-25-
MEASUREMENT WITH THE OUTER
CASE
REMOVED
(1) When you replace the magnetron, measure for
microwave energy leakage before the outer case
is installed and after all necessary components
are replaced or adjusted. Special care should be
taken in measuring the following parts.
-Around the magnetron
-The waveguide
WARNING: AVOID CONTACTING ANY HIGH
VOLTAGE PARTS.
MEASUREMENT WITH A FULLY
ASSEMBLED OVEN
(1) After all components, including the outer
panels, are fully assembled, measure for
microwave energy leakage around the door
viewing window, the exhaust opening and air
inlet openings.
(2) Microwave energy leakage must not exceed the
values prescribed below.
NOTES:
Leakage with the outer panels removed
than 5 mW/cm2.
Leakage for a fully assembled oven (before the
latch switch [primary] is interrupted) with the door
in a slightly opened position -less than 1 mW/cm2
NOTE WHEN MEASURING
(1) Do not exceed meter full scale deflection.
(2) The test probe must be removed no faster than
1 inch/sec (2.5cm/sec)along the shaded area,
otherwise a false reading may result.
(3) The test probe must be held with the grip portion
of the handle. A false reading may result if the
operator ʼs hand is between the handle and the
probe.
(4) When testing near a corner of the door, keep
the probe perpendicular to the surface making
sure to move the probe horizontally along the
oven surface. Doing so will avoid possible
damage to the probe.
RECORD KEEPING AND NOTIFICATION
AFTER MEASUREMENT
(1) After adjustment and repair of any microwave
energy interruption or microwave energy blocking
device, record the measured values for future
reference. Also enter the information on the
service invoice.
(2) Should the microwave energy leakage not be
more than 1 mW/cm2, determine that all parts are
in good condition, functioning properly
and that genuine replacement parts which are
listed in this manual have been used.
(3) At least once a year, have the electromagnetic
energy leakage monitor checked for calibration
by its manufacturer.
Summary of Contents for LMV1762SB
Page 7: ... 7 4 OPERATION 4 1 Control Panel 12 14 15 17 23 20 16 21 22 19 13 2 3 1 6 7 9 11 8 10 4 5 18 ...
Page 10: ... 10 5 2 Key Matrix KEY MATRIX KEY MATRIX ...
Page 14: ... 14 6 4 Troubleshooting No Display or Dead ...
Page 16: ... 16 Keypad Failure ...
Page 44: ...W102 4000 4002 4003 4001 4004 4002 LATCH BOARD PARTS EV ...
Page 48: ......