7-13
A. PRIMARY INTERLOCK SWITCH TEST
When the door is opened slowly, an audible click
should be heard at the same time or successively
at intervals and the latches should activate the
switches with an audible click.
If the latches do not activate the switches when the
door is closed, the switches should be a adjusted
in accordance with the adjustment procedure.
Disconnect the wire lead from the primary switch.
Connect the ohmmeter leads to the common
(COM) and normally open (NO) terminal of the
switch. The meter should indicate an open circuit
in the door open condition.
When the door is closed, the meter should indicate
a closed circuit.
When the primary switch operation is abnormal,
make the necessary adjustment or replace the
switch only with the same type of switch.
B. SECONDARY INTERLOCK SWITCH TEST
Disconnect the wire lead from the secondary
switch.
Connect the ohmmeter leads to the common
(COM) and normally open (NO) terminals of the
switch. The meter should indicate a open circuit in
the door open condition. When the door is closed,
meter should indicate an closed circuit. When the
secondary switch operation is abnormal, make the
necessary adjustment or replace the switch only
with the same type of switch.
C. MONITOR SWITCH TEST
Disconnect the wire lead from the monitor switch.
Connect the ohmmeter leads to the common
(COM) and normally closed (NC) terminals of the
switch. The meter should indicate closed circuit in
the door open condition. When the door is closed,
meter should indicate an open circuit. When the
monitor switch operation is abnormal, replace with
the same type of switch.
NOTE: After repairing the door or the interlock
system, it is necessary to do this continuity
test before operating the oven.
WARNING : FOR CONTINUED PROTECTION AGAINST EXCESSIVE RADIATION
EMISSION, REPLACE ONLY WITH IDENTICAL REPLACEMENT PARTS.
TYPE NO. SZM-V16-FA-63 OR VP-533A-OF FOR PRIMARY SWITCH
TYPE NO. SZM-V16-FA-62 OR VP-532A-OF FOR MONITOR SWITCH
TYPE NO. SZM-V16-FA-63 OR VP-533A-OF FOR SECONDARY SWITCH
COMPONENTS
TEST PROCEDURE
RESULTS
SWITCHES
Check for continuity of the
Door
Door
(Wire leads removed)
switch with an Ohm-meter
open
closed
Primary
Switch
Monitor
Switch
Secondary
Switch
NOTE : After checking for the continuity of switches, make sure that they are
connected correctly.
NO
COM
NC
COM
NC
COM
INTERLOCK CONTINUITY TEST
Summary of Contents for LMV1314B
Page 7: ...CONTROL PANEL 4 1 OPERATING INSTRUCTIONS 11 8 5 7 17 14 16 3 20 6 9 4 2 13 15 12 10 18 19 1 ...
Page 9: ...5 1 SCHEMATIC DIAGRAM OVERALL CIRCUIT DIAGRAM ...
Page 10: ...TIMER Ez On CUSTOM SET FRESH VEGETABLE 5 2 MATRIX CIRCUIT FOR TOUCH KEY BOARD ...
Page 36: ...8 1 EXPLODED VIEW DOOR PARTS 14890A 13536A 13552A 14970A 15006A 13213A 13720D 13581A 14026A ...
Page 37: ...8 2 CONTROLLER PARTS 24810P 23506A 23572A 24781M 268711 250201 24970A 24510L WTP018 ...
Page 39: ...8 4 LATCH BOARD PARTS 466001 43501A 43500A 466001 466003 ...
Page 42: ...8 7 INSTALLATION PARTS 63301M 65862B WTT028 65862D ...
Page 43: ...8 14 SCHEMATIC DIAGRAM OF P C B ...
Page 44: ...8 15 PRINTED CIRCUIT BOARD ...