7-16
COMPONENTS
TEST PROCEDURES
RESULTS
CIRCUIT BOARD
TOUCH KEY
BOARD
See page 7-19 for “CHECKOUT PROCEDURES FOR THE CIRCUIT BOARD”
NOTE: A MICROWAVE ENERGY LEAKAGE TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS
SERVICED FOR ANY REASON.
Measure the resistance between terminal
pins of connector KEY CON.
NOTE:
When reconnecting the FPC connector,
make sure that the holes on the FPC
connector are properly engaged with hooks
on the plastic fastener.
MATRIX CIRCUIT FOR
TOUCH KEY BOARD
CONNECTOR(KEY CON)
Figure 26
Resistance
value
When
When not
touched
touched
Less than More than
400 ohms 1 mega ohm
1
2
3
4
5
6
7
8
9
10
11
12
13
FPC CONNECTOR
Top
Figure 27
TIMER
Ez On
CUSTOM
SET
FRESH
VEGETABLE
Summary of Contents for LMV1314B
Page 7: ...CONTROL PANEL 4 1 OPERATING INSTRUCTIONS 11 8 5 7 17 14 16 3 20 6 9 4 2 13 15 12 10 18 19 1 ...
Page 9: ...5 1 SCHEMATIC DIAGRAM OVERALL CIRCUIT DIAGRAM ...
Page 10: ...TIMER Ez On CUSTOM SET FRESH VEGETABLE 5 2 MATRIX CIRCUIT FOR TOUCH KEY BOARD ...
Page 36: ...8 1 EXPLODED VIEW DOOR PARTS 14890A 13536A 13552A 14970A 15006A 13213A 13720D 13581A 14026A ...
Page 37: ...8 2 CONTROLLER PARTS 24810P 23506A 23572A 24781M 268711 250201 24970A 24510L WTP018 ...
Page 39: ...8 4 LATCH BOARD PARTS 466001 43501A 43500A 466001 466003 ...
Page 42: ...8 7 INSTALLATION PARTS 63301M 65862B WTT028 65862D ...
Page 43: ...8 14 SCHEMATIC DIAGRAM OF P C B ...
Page 44: ...8 15 PRINTED CIRCUIT BOARD ...