• Do not locate the solar module horizontally, as this may cause dirt or white efflorescence (glass

deformation)

• Do not cover the water drain hole of the frame. Doing so causes the risk of frost damage when the

frame is filled with water.

• Please handle the module with care.
• Do not place an excessive load on the module. The solar cell is very thin and will break easily under

excessive weight.

• Do not stand or step on the module.
• Do not drop the module or allow objects to fall down on the module.
• Do not damage, scratch, or hit the rear surface of the module.
• Do not hit the junction box or pull the cables.
• Do not lift the module by grasping the junction box.
• Do not disassemble, modify or adapt the module or remove any part or label.
• Do not drill holes in the frame or glass. It may decrease frame or glass strength.
• Do not scratch the insulation coating of the frame (except for a grounding connection), as doing so

may cause corrosion of the frame or decrease the framework strength.

• Do not apply paint or adhesives to the rear surface of the module.
• Never leave the module unsecured.
• A module with broken glass or back skin has peeled off must not be used.
• Broken or damaged modules must be handled carefully with appropriate protective equipment.

- Handling Safety

• Keep the system and modules away from children when installing.
• Keep the module packed in the carton until the time of installation.
• Do not touch the module more than during installation. 

The glass surface and the frames heat up, so there is a risk of being burned or shocked when touch-
ing.

• Do not work under raining, snowing, or windy conditions.
• Use insulated tools and rubber gloves approved for working on electrical equipment.
• Do not use wet tools.
• When installing modules high above the ground, take precautions to avoid dropping the module or

tools.

• Make sure the flammable gases are not generated near the installation site.
• Completely cover the module surface with an opaque material during the module installation and

wiring work.

• Plug the connector in tightly and ensure that the wiring works.
• Do not perform any work if the terminals of module are wet due to the risk of electrical shock.
• Do not touch junction box or cable ends (connectors) with bare hand during the installation or

under sunlight, regardless of whether the module is connected or disconnected from the system.

• Do not unplug the connector if the system circuit is connected to a load.
• Do not work alone. Please work as part of a team of two or more people.
• Wear a safety belt if working high above the ground.
• Do not wear metallic jewelry while performing mechanical or electrical installation.

- Installation Safety 

Summary of Contents for LG M1C Series

Page 1: ......

Page 2: ...rical Installation 6 Electrical Connections 6 General Wiring 6 Earth Ground Wiring 6 Series Connection 6 Parallel Connection 7 5 Mechanical Installation 7 Module Mounting 7 Site Consideration 7 Mounting Configurations 8 Mechanical characteristics All types 11 6 Product Specification 12 Mono crystalline 12 Poly crystalline 13 7 Ground method 14 ...

Page 3: ...ct with electrically active parts of the solar module such as terminals could result in burns sparks and lethal shock whether the module is connected or not Installation or maintenance should only be performed by qualified professionals in accordance with local requirements No matter where the modules are installed whether on roof mounted construction or any other type of above ground structure ap...

Page 4: ...ate protective equipment Handling Safety Keep the system and modules away from children when installing Keep the module packed in the carton until the time of installation Do not touch the module more than during installation The glass surface and the frames heat up so there is a risk of being burned or shocked when touch ing Do not work under raining snowing or windy conditions Use insulated tool...

Page 5: ...Page 5 3 Component Front Type A Type B Glass Solar Cell Mono Glass Solar Cell Poly Back Junction Box Backsheet Frame ...

Page 6: ...ith a minimum rating of 90 C 194 F All wiring should use a flexible copper Cu conductor The minimum size should be determined by the applicable codes We recommend a size not smaller than 4mm2 Earth Ground Wiring To prevent electric shock and fire an earth ground must be done on the frames of Photovoltaic solar modules modules and arrays There is an earth hole in the center of the module frame Usin...

Page 7: ...s for the protection of the module and cables from over current and or bloking diodes for prevention of unbalanced string voltage Module Mounting The LG Electronics LGE Limited Warranty for solar modules is contingent upon modules being mount ed in accordance with the requirements described in this section Application class A 5 Mechanical Installation Site Consideration LGE solar modules should be...

Page 8: ...angle from horizontal to vertical Select the appropriate orien tation to maximize sunlight exposure Specific information on the solar module dimensions and loca tion of mounting and grounding holes is provided below In order to prevent water from entering the junction box which could present a safety hazard module should not be mounted such that the front top glass faces downward Clearance between...

Page 9: ...nsions and mounting hole locations The module may be fastened to a support using the bolt holes in the bottom of the frame at location A refer to Figure 1 The module should be fastened with M6 bolts plain washers spring washers and nuts for support A gap between the solar module frame and the installation object is necessary for cooling air circu lation Do not seal this gap The recommended standof...

Page 10: ...solar modules as shown in Figures 2 and 3 Note that the clip positions are maintained the clip centerlines must be between 7 and 16 from the end of the module A B C Figure 2 A 30mm min Catch Length B 5mm min Catch Width C 10mm min Support Width B Mounting using clips on the long edge of the module ...

Page 11: ...Mechanical characteristics All types Mounting slots 8 places Junction Box Detail A Scale 1 5 Detail B Scale 1 5 Detail C Scale 1 5 Grounding holes 4 places Drain holes 4 places Drain holes 8 places 993 954 993 2 4 3 11x6 5 2 5 5 6 5 11 6 12 R3 R3 25 12x5 1649 23 4 370 205 105 42 Figure 4 ...

Page 12: ...49A 235W 3 0 1 000V 15A 60each 3 3 15A each 0 47 K 0 05 K 0 34 K 36 9V 29 7V 8 10A 8 58A 240W 3 0 1 000V 15A 60each 3 3 15A each 0 47 K 0 05 K 0 34 K 6 Product Specification Voc Vmp Imp Isc Pmax Output Tolerance Maximum System Voltage Maximum Series Fuse Total Number of Cells Total Number of Strings Diodes Rating Temperature coefficient of power TkPmax Temperature coefficient of current TkImp Temp...

Page 13: ... 0V 7 76A 8 30A 225W 3 0 1 000V 15A 60each 3 3 15A each 0 47 K 0 05 K 0 34 K 36 4V 29 1V 7 91A 8 39A 230W 3 0 1 000V 15A 60each 3 3 15A each 0 47 K 0 05 K 0 34 K Voc Vmp Imp Isc Pmax Output Tolerance Maximum System Voltage Maximum Series Fuse Total Number of Cells Total Number of Strings Diodes Rating Temperature coefficient of power TkPmax Temperature coefficient of current TkImp Temperature coef...

Page 14: ...imension material Remark Hexagon nut bolt Plain washer Toothed lock washer Screw washer Ground wire M4 stainless M4 stainless M4 stainless M4 stainless 12 AWG copper The length of the bolt 15 mm F B E D A B C B Bolt A Plain Washer B Toothed Lock Washer C Grounding Wire D Screw Washer E Nut F Figure 5 7 Ground method ...