- 60 -
12. TROUBLESHOOTING
Month
1 : January
O : October
N : November
9 : September D : December
~
The information tag provides compressor model, refrigerant, serial number and safety approval
There are two types of controllers used in the linear compressor system.
- The “E”-inverter system is used with the FC75LANE compressor.
Name Plate
Compressor Label
12-1 INFORMATION OF LINEAR COMPRESSOR
FC75LANE
Size : 90mm X 20mm
!
"
1. Compressor Model
2. Refrigerant
3. Serial Number
4. Safety Approval
Ex)
F C 7 5 L A N E
00 00 9 2003 5 13 0012
Series name
DLF/FA/FB
Operating Type
A : A-Inverter
E : E-Inverter
Rated Voltage
& Frequency
- M : 220V 50/60Hz
- N : 115V 50/60Hz
Efficiency version
A : 1
st
generation
B : 2
nd
generation
Displacement
ex)90=9.0
cm
3
/stroke
Application Category
- L : LBP with R134a
- H : HBP with R134a
- N : LBP with R600a
Buyer Code
Model Code
Line
Serial No.
Date
Year
**CVCF : Constant Voltage Constant Frequency
FC75LANE
E-Inverter
System
Refrigerator
Comp On/Off
Comp Drive
Inverter
CVCF
Compressor
Self
Modulation
Summary of Contents for LFX25976ST
Page 21: ... 21 5 CIRCUIT DIAGRAM 5 1 LMX28988 ...
Page 22: ... 22 5 2 LMX25988 ...