- 32 -
8-6 Freezer Fan Error (Er FF)
No
1
2
Checking flow
Reset the unit and
Input Test 1 Mode.
(Push the button 1 time)
Open the freezer door and Check the air
flow.
※
While an error code is displayed,
the fan is not working.
3
Check the Fan motor.
Rotate fan using your hand.
If it is stuck, change the motor.
(Cause of ice or rust inside of motor)
4
Check the Fan motor voltage.
Result & SVC Action
Below 12 V
0 or 5 V
(1) ~ (2)
(2) ~ (3)
Change the PCB
Change the motor
Point
Result
SVC Action
<CON4>
(2)
Status
No windy
Windy
SVC Action
Go to 3
Go to 4
(3)
(1)
Summary of Contents for LFX25976ST
Page 21: ... 21 5 CIRCUIT DIAGRAM 5 1 LMX28988 ...
Page 22: ... 22 5 2 LMX25988 ...