8-7 Icing Fan Error (Er IF)
No
1
2
Checking flow
Reset the unit and
Input Test 1 Mode.
(Push the button 1 time)
Open the refrigerator door and Check the
air flow.
※
While an error code is displayed,
the fan is not working.
3
Check the Connector
(Frozen caused the PCB short)
※
Tip
To prevent ice from shorting the
connector a new connector was
developed.
Make sure to order the new one.
4
Check the Fan motor.
(Frozen, Lock, ect.)
Result & SVC Action
4
Check the Fan motor voltage.
Below 12 V
0 or 5 V
(1) ~ (2)
(2) ~ (3)
Change the PCB
Change the motor
Result
SVC Action
Duct Asm,
Connector
407A
5209JA
1044A
5209JA
1044A
Part Name
Old P/No
New P/No
No
Status
No windy
Windy
SVC Action
Go to the 3,4
Go to the 5
Wire seal (Silicon)
<CON4>
(2)(3)
(1)