- 62 -
3) Refrigerator LED Lamp not working
1
Check for loose connection in CON6
No
Checking flow
Result & SVC Action
2
Check Voltage between Red and Black
wires.
Result
SVC Action
11~12VDC
Go to step #3
Other Value
Replace Main PCB.
Result
SVC Action
Firmly plugged
Go to step #2
Loose
Plug firmly, then check again. Problem
persist?
YES: go to step #2
NO: explain to customer.
3
Check for loose connection in harness
joint, located in Case Main PCB.
Result
SVC Action
Firmly plugged
Go to step #4
Loose
Plug firmly, then check again. Problem
persist?
YES: go to step #4
NO: explain to customer.
Summary of Contents for LFC20770SB
Page 23: ...6 CIRCUIT DIAGRAM 22 CIRCUIT DIAGRAM ...
Page 24: ...CIRCUIT DIAGRAM 23 ...
Page 27: ...7 2 PCB FUNCTION CON 1 CON 3 CON 2 CON 8 CON 9 CON 7 CON 6 CON 5 CON 4 26 ...
Page 37: ... 36 LED Lamps P No LED Lamp R EAV61711901 Picture LED Lamp F EAV60892210 ...