- 46 -
4
1-. Cut Room temperature Sensor.
No
Checking flow
Result & SVC Action
Result
SVC Action
Open Circuit
Go to step #5
Other Value
Replace Refrigerator unit.
5
1-. Twist wire ends.
2-. Check resistance value in brown to
brown in CON8
2-. Strip the wire ends.
3-. Check resistance value between wires
brown to brown in CON8.
*Representative picture.
NOTE: Keep wire ends separated during measurement.
Result
SVC Action
0Ù
Replace Room Temperature sensor.
Other Value
Replace Refrigerator unit.
*Representative picture.