1-. Remove Cover LED LAMP.
2-. Check Voltage between Red and
Black wires as is shown in the picture.
No
Checking flow
Result & SVC Action
Result
SVC Action
Freezer Door
S/W pressed
11~12VDC
Check in released condition.
0VDC
Replace Door Switch
Freezer Door
S/W released
0VDC
Replace LED Lamp
Other
Replace Refrigerator unit.