background image

Owner’s Manual 

3

ENGLISH

Safety Precautions  

To prevent injury to the user or other people and property damage, the following instructions
must be followed.

Incorrect operation due to ignoring instructions will cause harm or damage. The seriousness
is classified by the following indications.

Because of the weight of the product, it is recommended that you have a helper to assist in
the installation.

Meanings of symbols used in this manual are as shown below.

WARNING

CAUTION

This symbol indicates the possibility of death or serious injury.

This symbol indicates the possibility of injury or damage to properties only.

WARNING

Installation

Be sure not to do.

Be sure to follow the instruction.

Safety Precautions

Don’t use a power cord, a
plug or a loose socket
which is damaged.

• Otherwise, it may cause a fire

or electrical shock.

Always plug into a
grounded outlet.

• Otherwise, it may cause a fire

or electrical shock.

Do not modify or extend the
power cord length.

• It will cause electric shock or

fire due to heat generation.

Do not disassemble or
modify products.

• It may cause failure and

electric shock.

Be caution when unpacking
and installing.

• Sharp edges may cause

injury.

Do not use the power cord near
flammable gas or combustibles
such as gasoline, benzene,
thinner, etc.

• It may cause explosion or fire.

Gasolin

Summary of Contents for LA1000PR

Page 1: ...ation about your air conditioner This manual may help save time and money by explaining proper air conditioner maintenance and preventing improper use Pay close attention to precautions in order to prevent potential hazards and damage from misuse or improper installation LG is not responsible for any damages caused by misuse of the air conditioner ENGLISH ESPAÑOL ...

Page 2: ... chart of Troubleshooting Tips first you may not need to call for service at all PRECAUTION Contact an Authorized Service Center for repair or maintenance of this unit Call 1 877 714 7486 to locate the nearest ASC The air conditioner is not intended for use by young children or invalids without supervision Young children should be supervised to ensure that they do not play with the air conditioner...

Page 3: ... indicates the possibility of injury or damage to properties only WARNING Installation Be sure not to do Be sure to follow the instruction Safety Precautions Don t use a power cord a plug or a loose socket which is damaged Otherwise it may cause a fire or electrical shock Always plug into a grounded outlet Otherwise it may cause a fire or electrical shock Do not modify or extend the power cord len...

Page 4: ... a strong detergent The appearance of the air conditioner may deteriorate change color or develop surface flaws Unplug the unit if strange sounds odors or smoke come from it Otherwise it may cause fire and electric shock accident Do not open the suction inlet grill of the product during operation Otherwise it may electrical shock and failure If water enters the product turn off the the power switc...

Page 5: ...he head when taking it out It may cause electric shock and damage When gas leaks open the window for ventilation before operating the unit Otherwise it may cause explosion and a fire Never touch the metal parts of the unit when removing the filter They are sharp and may cause injury CAUTION Installation Install the product so that the noise or hot wind from the outdoor unit may not cause any damag...

Page 6: ...oor outdoor unit and do not put anything on it It may cause an injury through dropping of the unit or falling down Always insert the filter securely Clean it every two weeks Operation without filters will cause failure Do not drink water drained from air conditioner It contains containments and will make you sick Be cautious not to touch the sharp edges when installing It may cause injury Avoid ex...

Page 7: ...g precision devices food pets plants and art objects Such usage could damage the items 4 The air conditioner is a consumer comfort appliance not a precision climate control system 1 Do not touch the metal parts of the unit when removing the filter Injuries can occur when handling sharp metal edges 2 Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation l...

Page 8: ...This appliance should be installed in accordance with the National Electric Code Control Board Front Grille Cabinet Curtain Hand Grip Vertical Air Direction Louvers Air Filter Inside Front Panel Horizontal Air Direction Louvers Power Cord Evaporator Base pan Condenser Compressor Control Box POW ER TEM P T IME SLE EP TIM ER MO DE FAN SPE ED AIR PUR IFIE R Remote Control Introduction Symbols Used in...

Page 9: ...es will create an unsafe condition that could result in fire or electrical shock Refer all such work to a licensed and qualified electrician WARNING Do not cut or remove the grounding prong from the power plug WARNING Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated and the wall receptacle is gr...

Page 10: ...m the adapter use one hand on each to avoid damaging the ground terminal Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage WARNING Never use the appliance with a broken adapter We strongly discourage the use of an extension cord due to potential safety hazards For temporary situations use only CSA certified and UL listed 3 wire grounded extension cords ...

Page 11: ...window is required for proper installation Non window installations including using sleeves holes in walls and other installations are not recommended Have the following tools available for installation Tight Fitting gloves Standard screwdriver Phillips screwdriver Pliers Sharp knife 3 8 inch open end wrench or adjustable wrench 1 4 inch hex socket and ratchet Tape measure Electric drill 1 4 inch ...

Page 12: ... sill as shown in FIG 2 3 Install support bracket on window See FIG 3 Install leveling bolt up through bottom side of support bracket You can choose a short bolt ITEM C or a long one ITEM B according to window type Also you should select the position of hole on bracket Position bracket on sill on the center line of window See FIG 3 Fasten bracket loosely to sill with screws ITEM D provided Adjust ...

Page 13: ... getting into the room as shown in FIG 7 Install the L bracket to prevent window from being raised which may result in unit falling Attach the side bracket ITEM J in the inner window sill with a screw ITEM E as shown in FIG 8 after removing the existing screw at right bottom side on cabinet If window sash has a metal surface use sheet metal screws instead of the provided wood screws Obtain sheet m...

Page 14: ... Page 13 Close the curtain frame and remove foam seal and L bracket from the windows Keep a firm grip on the air conditioner and raise the sash Lift the air conditioner from the window Remove the foam strip from between the window Remove the support bracket from window frame Place unit and mounting hardware in air conditioner shipping carton and store in clean dry place INNER SILL WOOD STRIP MOUNT...

Page 15: ... time the fan speed button is pressed the fan speed mode is shifted TIMER SHUT OFF TIME You will usually use shut off time while you sleep If unit is running use Timer to set number of hours until shut off You can control your timer setting up and down with TEMP TIME button START TIME If unit is off use Timer to set number of hours before unit starts You can control your timer setting up and down ...

Page 16: ...the Air Purifier button Operation will start when the button is pressed and stop when the button is pressed again You can select the fan speed in three settings High Low or Medium Each time the button is pressed the fan speed mode is shifted If you press only the Air Purifier button only air purifying operates without cooling You can select the fan speed in three settings High Low or Medium Each t...

Page 17: ...ove the Drain Cap and secure the Drain Pipe to the rear hole of the Base Pan Press the drain pipe into the hole by pushing down and away from the fins to avoid injury This air conditioner is equipped with a slinger fan The fan has an outer ring that runs in the water that collects in the base pan if it gets deep That condensate is then picked up by the fan and expelled through the condenser making...

Page 18: ... air filter Wash the Air Filter under the faucet with warm water Be sure to shake off all the water before replacing the filter Air Conditioner Cleaning Clean the front grille and inlet grille by wiping with a cloth dampened in a mild detergent solution The cabinet may be washed with mild soap or detergent and lukewarm water then polished with liquid appliance wax To ensure continued peak efficien...

Page 19: ...f the grille away from the case to lift the top tabs out of their slots Disconnect display connector HOW TO REPLACE THE FRONT GRILLE Connect display connector Attach the front grille to the cabinet by inserting the tabs on the grille into the slots on the front of the cabinet Push the grille in until it snaps into place and secure it with 2 screws at bottom sides Front Grille ...

Page 20: ...nning while the compressor is silent This is a normal operational feature Common Problems and Solutions Before Calling for Service If you have problems with your air conditioner read the following information and try to solve the problem If you cannot find a solution turn off the air conditioner and contact your dealer Air conditioner does not operate 1 Ensure that the air conditioner is plugged i...

Page 21: ...r The air filter is dirty The air conditioner was just turned on Cold air is escaping Cooling coils are iced up The cooling coils are iced over Make sure the plug is completely plugged into the outlet Check the fuse circuit breaker box and replace the fuse or reset the breaker In the event of a power failure set the power control to OFF When the power is restored wait 3 minutes to restart the air ...

Reviews: