Installation of Indoor, Outdoor Unit
Installation Manual
15
Ceiling Concealed Duct Type
■
Installation of Unit
Install the unit above the ceiling correctly.
• Apply a joint-canvas between the unit and
duct to absorb unnecessary vibration.
• Apply a filter Accessory at air return hole.
• Install the unit leaning to a drainage hole
side as a figure for easy water drainage.
• A place where the unit will be leveled and
that can support the weight of the unit.
• A place where the unit can withstand its
vibration.
• A place where service can be easily
performed.
CASE 1
POSITION OF SUSPENSION BOLT
CASE 2
POSITION OF CONSOLE BOLT
(Unit:mm)
Drainage hole
A
B
C
1-3 mm
D
(G)
H
I
E
F
M10 SP. washer
M10 washer
M10 Nut
X 8
X 4 (Local
supply)
X 4
M10 Nut
M10 SP. washer
M10 washer
X 4
X 4
(Local
supply)
X 8
18 kBtu/h
932 880 355 45.5 450
30
87
750 163
24 kBtu/h
30 kBtu/h
1 232 1 180 355 45.5 450
30
87
830 186
36 kBtu/h
48 kBtu/h
1 292 1 230 477
56
590
30
120 1 006 294
Dimension
Capacity
A
B
C
D
E
F
(G)
H
I
Summary of Contents for L5UC728FA2