14
Multi Type Air Conditioner
Installation of Indoor, Outdoor Unit
The wall you select should be strong and solid
enough to prevent vibration
1. Mount the installation plate on the wall with
type "A" screws. If mounting the unit on a
concrete wall, use anchor bolts.
• Mount the installation plate horizontally by
aligning the centerline using a level.
2. Measure the wall and mark the centerline. It
is also important to use caution concerning
the location of the installation plate-routing
of the wiring to power outlets is through the
walls typically. Drilling the hole through the
wall for piping connections must be done
safely.
■
How to fix installation plate
• Drill the piping hole with a ø70mm hole core
drill. Drill the piping hole at either the right or
the left with the hole slightly slanted to the
outdoor side.
■
Drill a hole in the wall
5-7mm
(3/16"~5/16")
Indoor
WALL
Outdoor
Standard
Chassis
Hook
Installation Plate
Type “A”
Installation plate
Left rear piping
Right rear piping
Ø70mm
Ø70mm
D
B
A
C
<Type 1>
<Type 1>
Installation plate
Left rear piping
Right rear piping
Ø70mm
133mm
Ø70mm
100mm
<Type 2>
Chassis
Hook
Installation Plate
Type “A”
<Type 2>
Wall mounted
12
55
105
65
105
1
18,24
100
122
240
122
2
ART COOL Mirror
12
70
110
90
110
1
18,24
100
122
240
122
2
Indoor Type
Capacity
(kBtu/h)
Distance (mm)
Type
A
B
C
D
Summary of Contents for L5UC728FA2