Installation Manual
7
Installation of Indoor, Outdoor Unit
Installation of Indoor, Outdoor Unit
Read completely, then follow step by step.
1. Indoor unit
• Do not have any heat or steam near the unit.
• Select a place where there are no obstacles in
front of the unit.
• Make sure that condensation drainage can be
conveniently routed away.
• Do not install near a doorway.
• Ensure the spaces indicated by arrows from
the wall, ceiling, fence or other obstacles.
• Use a stud finder to locate studs to prevent
unnecessary damage to the wall.
Install the air conditioner in the location that
satisfies the following conditions.
• The place shall easily bear a load exceeding
four times the indoor unitʼs weight.
• The place shall be able to inspect the unit as
the figure.
• The place where the unit shall beleveled.
• The place shall allow easy water
drainage.(Suitable dimension “H” is necessary
to get a slope to drain as figure.)
• The place shall easily connect with the
outdoor unit.
• The place where the unit is not affected by an
electrical noise.
• The place where air circulation in the room will
be good .
• There should not be any heat source or steam
near the unit
Select the best location
More than 20 cm
More than
10 cm
More than 2.3 m
More than 2.3 m
More than
10 cm
More than 20 cm
More than 10 cm
More than
10 cm
H
600
600
Top view
(unit: mm)
Front view
Front
Inspection Hole
(600X600)
Inspection Hole
(600X600)
Control box
1000
CAUTION: Install the indoor unit
on the wall where the height from
the floors more than 2.3 meters.
Wall mounted Type
Duct Type