14
Multi Type Air Conditioner
Installation of Indoor, Outdoor Unit
The wall you select should be strong and
solid enough to prevent vibration
1. Mount the installation plate on the wall with
type "A" screws. If mounting the unit on a
concrete wall, use anchor bolts.
• Mount the installation plate horizontally by
aligning the centerline using a level.
2. Measure the wall and mark the centerline.
It is also important to use caution
concerning the location of the installation
plate-routing of the wiring to power outlets
is through the walls typically. Drilling the
hole through the wall for piping connections
must be done safely.
n
How to fix installation plate
Installation Plate
Type "A" screw
Installation plate
Ø70mm
Left rear piping
Right rear piping
C
D
B
A
Ø70mm
Left rear piping
Right rear piping
B
A
D
C
Installation plate
(SR, ST, SU)
(S3)
• Drill the piping hole with a ø70mm hole core
drill. Drill the piping hole at either the right or
the left with the hole slightly slanted to the
outdoor side.
n
Drill a hole in the wall
5-7mm
(3/16"~5/16")
Indoor
WALL
Outdoor
Standard
SR(12 kBtu/h)
0
40
20
40
ST(18 kBtu/h~24 kBtu/h)
105
0
210
0
SU(12 kBtu/h)
92
44
67
44
S3(18 kBtu/h~24 kBtu/h)
58
3
292
3
CHASSIS (Capacity)
Distance (mm)
A
B
C
D
Summary of Contents for L5UC728FA0