FAILURE MODE FLOW CHART
LGE Internal Use Only
Copyright © 2009 LG Electronics. Inc. All right reserved.
Only for training and service purposes
No Ignition
Turn a knob to “LITE”
position
See the spark
of the burner?
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Check the
gas supply
Ignite flames on
the burner?
Check the
connection
of the power
cord
Connect the power
cord to
power supply
Check the power cord wire,
L1, N, G.
WARNING
: Disconnect the
power supply. Before
checking the power cord.
Normal?
Is it prperly
connected?
Check the connection of
the connectors.
1
1
Replace the
power cord
1
Connect the
connectors
1
4
3
2
No
END
Is it properly
connected?