-40-
LGE Internal Use Only
Copyright © 2009 LG Electronics. Inc. All right reserved.
Only for training and service purposes
C. Install the LP orifice spuds into their correct positions as showen below picture and tables.
D. To prevent leakage, make sure the orifice spuds are securely screwed intothe gas supply tubes.
E. For the Center burner of LCG3011ST, LCG3611ST, the choke and self threading screw will
be needed as shown Fig Insert the choke into the burner base, then insert the set screw
into the burner base and tighten securely. Make sure the screw head is against the
shoulder (within choke notch), so it does not have any rotational movement.
CONVERSION TO LP GAS
F
F
M
G
H
A
A
L
B
C
F
F
M
G
H
A
A
L
B
C
Self threading screw
Choke
17k burner base
BURNER OUTPUT RATINGS;BTU/HR
LP or Propane Gas, 10~W.C.P
BTU RATE
ORIFICE CODE
LCG3611** LCG3011** LCG3611** LCG3011**
LF
9100
9100
F
F
LR
9100
9100
F
F
RR
5000
5000
G
G
RF
9500
9500
H
H
CTR
10000
10000
J
J
K
K
BURNER OUTPUT RATINGS;BTU/HR
Natural Gas, 5” W.C.P
BTU RATE
ORIFICE CODE
LCG3611** LCG3011** LCG3611** LCG3011**
LF
9100
9100
A
A
LR
9100
9100
A
A
RR
5000
5000
B
B
RF
12000
12000
C
C
CTR
17000
17000
D
D
E
E
BURNER
BURNER
MODEL
MODEL
Summary of Contents for HG7522KR.ABDELGA