Chapter 7. MK PROGRAMMING
7 - 18
Reading the current count value
of the high speed counter
module to D0010 and D0011
If the turntable has rotated
138(
≒
50
˚
), then the low
speed operation turns On
If the turntable has rotated 60
˚
with low speed, it will be stopped
by the coincidence signal (“=”) of
OUT1
Setting the Preset value to ‘0’ to
change the current count value
into ‘0’
.
Preset signal complementary
contact
Coincidence reset signal
turns On.
After the drilling work has been
repeated six times, the processing
complete signal (C000) turns On.
High-speed operation
turns On.
Preset signal
turns On.
complete signal switch
Process complete signal