Dry Fan Motor Trouble
Is the
Connector
connected correctly to
the
Main PCB
and the
Dry Heater
or
Fan Motor
?
Or is the
Harness
alright?
Are the resistance same between
terminal
points?
V~U / U~W / W~V : 2~5Ω
When checking voltage between
connectors(1,2)
on drying, is the voltage DC 20~30V as the figure ?
Reconnect or repair the
Connector
.
Or replace the
Harness
.
Replace the
Dry Fan Motor
.
Replace the
PWB assembly
(main)
.
U V W
YES
YES
NO
NO
NO