Power off for 10sec. Then power on.
Is the water level over reference line and is the water level f requency under 21.3kHz?
* Water level frequency
- Touch and Hold
'Sp
in
' & 'Turbo Wash'
simultaneously.
FE (Overflow Error)
If FE is displayed again,
then replace the
Pressure Switch
.
If FE is displayed again,
then replace the
Main PCB
.
Drain out the water and then
check the
Air Chamber
and the
Tube
(clogged).
NO
NO
YES
YES
Is water
continuously
coming into the drawer?
Replace the
Main PCB.
Replace the
Inlet Valve
assembly.