Dry Heater Error (dHE)
Is the
Connector
connected correctly to
the
Main PCB
and the
Dry Heater or Fan Motor?
Or is the
Harness
alright?
Reconnect or repair the
Connector
.
Or replace the
Harness
.
Clean the
Bellows
.
Replace the
Thermistor
.
Is the resistance of t.he
Thermistor
out of range
2.5 ~ 180KΩ at 105 ~ 0°C
?
Disassemble the
Cabinet cover
and
Condensing Bellows.
Is there any foreign object in
Condensing Bellows
?
Disassemble the
Dry Fan Assy and Dry Duct Upper,
and clean foreign object in
Duct and Fan
.
Check for
Dry Heater
trouble.
Page 41
Check for
Dry Fan Motor
trouble.
Page 42
YES
YES
YES
YES
YES
NO
NO
NO