Troubleshooting
40
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
Code
Description
Solution
B467
MUC PIE handler error
Automatically restart after releasing fault
B468
MCU ROM ECC error
Automatically restart after releasing fault
B469
MCU RAM ECC error
Automatically restart after releasing fault
B470
MCU clock error
Automatically restart after releasing fault
B471
MCU RAM 1 error
Automatically restart after releasing fault
B472
MCU RAM 2 error
Automatically restart after releasing fault
B473
MCU oscillator source error
Automatically restart after releasing fault
B600
Cell Voltage level of battery cell is higher
than the limit
Contact service center
B601
Cell Voltage level of battery cell is lower than
the limit
Contact service center
B603
Unit Voltage level of battery cell is higher
than the limit
Contact service center
B604
Unit Voltage level of battery cell is lower
than the limit
Contact service center
B606
Cell voltage difference between battery cells
is higher than the limit
Contact service center
B607
Pack voltage difference between battery
packs in higher than the limit
Contact service center
B650
Discharge current level is higher than the
limit
Contact service center
B651
Charge current level is higher than the limit
Contact service center
B653
Discharge Atmosphere temperature level is
higher than the limit
Contact service center
B654
Discharge Atmosphere temperature level is
lower than the limit
Contact service center
B655
Charge Atmosphere temperature level is
higher than the limit
Contact service center
B656
Charge Atmosphere temperature level is
lower than the limit
Contact service center
B700
Discharge temperature level is higher than
the limit
Contact service center
B701
Discharge temperature level is lower than
the limit
Contact service center
B702
Charge temperature level is higher than the
limit
Contact service center
B703
Charge temperature level is lower than the
limit
Contact service center