39
Caution
Trouble Symptom
Measurement Condition
Before measuring resistance, be sure to turn power off, and do voltage discharge.
(When discharging, contact the metal plug of power cord with the ground wire.)
During the diagnostic test, E5 error occurs.
Turn the dryer’s power off, then measure resistance.
After activating the *diagnostic test, press the
START/PAUSE button 4 times.
Is AD value displayed higher than 10 ?
Note :
Let the dryer start each test step
Before continuing to the next. If you press
the button in rapid-fire succession, you
could damage the main board.
YES
NO
• Replace th
e
DC pump
Normal condition
* see page 26 for diagnostic test information.
Test 8
Motor Assembly, DC, Pump
Test 9
Generator Assembly
Caution
Trouble Symptom
Measurement Condition
Before measuring resistance, be sure to turn power off, and discharge voltage.
(When discharging, contact the metal plug of power cord with the ground wire.)
During steam cycle, generator assembly is not heating.
During diagnostic test, tE4 error occurs.
Turn the dryer’s power off, then measure resistance.
Is resistance 14.3
Ω
( 5%) between heater
terminal
and
?
YES
NO
• Replace th
e
generator
assembly
• If the measured
resistance is out of
spec, replace the
steam generator
assembly.
Normal condition
Summary of Contents for DLEX8000
Page 11: ...11 Connecting electric dryers ...
Page 15: ...15 Connecting Electric Dryers cont USA only ...
Page 21: ...21 7 WIRING DIAGRAM 23 7 WIRING DIAGRAM ...
Page 52: ...52 13 EXPLODED VIEW 54 A211 A210 A120 A110 A130 F211 F215 13 EXPLODED VIEW ...
Page 53: ...53 55 K503 K508 K501 A090 K507 K505 K502 A160 A170 K504 K506 A161 A172 A171 A350 ...