33
Test 2
Thermistor Test --- Measure with Power Off
Before measuring resistance, be sure to turn the power off and discharge voltage.
(When discharging, contact the metal plug of power cord with the ground.)
During diagnostic test, tE1 and tE2, an error occurs.
During operation, the heater does not turn off.
Difference between actual and sensed temperature is significant.
After turning power off, measure the resistance.
Measure the resistance between the
NA8-
③
(BL) and NA8-
②
(YL) Does the
resistance measured match the temperature
of the thermistor in the chart? (Use room
termistor is warm from running the dryer.)
• C
heck if control
and the 8 Pin
connector are
properly
connected.
• R
eplace
controller
• R
eplace
thermistor.
Check if resistance is in the range of T
able 1
when measuring resistance between
terminals after separating harness
from thermistor assembly connector.
Check harness-linking connector
.
NO
NO
YES
YES
Table 1. Resistance for Thermistor T
emperature.
Air TEMP.
[°F( )]
50°F (10 )
60°F (16 )
80°F (21 )
70°F (27 )
Air TEMP.
[°F( )]
90°F (32°C)
100°F (38°C)
11
0°F (43°C)
120°F (49°C)
RES.
[KΩ]
18.0
14.2
11.7
9.3
RES.
[KΩ]
7.7
6.2
5.2
4.3
RES.
[KΩ]
2.9
3.0
2.5
2.2
Air TEMP.
[°F( )]
130°F (54 )
140°F (60 )
150°F (66 )
160°F (71 )
Caution
Trouble Symptom
Measurement Condition
T
ake NA8 Connector from
the Controller
.
Summary of Contents for DLEX8000
Page 11: ...11 Connecting electric dryers ...
Page 15: ...15 Connecting Electric Dryers cont USA only ...
Page 21: ...21 7 WIRING DIAGRAM 23 7 WIRING DIAGRAM ...
Page 52: ...52 13 EXPLODED VIEW 54 A211 A210 A120 A110 A130 F211 F215 13 EXPLODED VIEW ...
Page 53: ...53 55 K503 K508 K501 A090 K507 K505 K502 A160 A170 K504 K506 A161 A172 A171 A350 ...