DRYER CYCLE PROCESS
Cycle
Default
Conditions of operation and termination
Temp-
erature
Dry
Level
Display
time
Drying
Cooling
Wrinkle care
Time
Electro-
sensor
Temp-
Control
Default
time
Temp-
Control**
Load
Motor
Heater
Temperature Control for each cycle
Off Time: 6 min
On Time: 10 sec
*Sensor dry : Dry Level is set by users.
**Manual dry : Temperature control is set by users.
Default settings can be adjusted by users.
DLEX8000* / DLGX8001*
DLEX8100* / DLGX8101*
Sensor
Dry
STEAM FRESH
TM
ANTI
BACTERIAL
PERM PRESS
COTTON/NORMAL
DELICATES
TOWELS
WOOL
JUMBO DRY
HEAVY DUTY
SPOT CLEAN
SUPER DRY
STEAM
SAINTARY
TM
TM
MID HIGH
MID HIGH
MEDIUM
MEDIUM
MEDIUM
Very DRY
HIGH
HIGH
HIGH
HIGH
LOW
LOW
LOW
20 min
Saturation
Saturation
Saturation
Saturation
Saturation
Saturation
Saturation
Saturation
Saturation
Saturation
64
±
2˚C
45
±5
˚C
45
±5
˚C
45
±5
˚C
45
±5
˚C
45
±5
˚C
45
±5
˚C
45
±5
˚C
45
±5
˚C
45
±5
˚C
45
±5
˚C
45
±5
˚C
38
±5
˚C
66
±
2˚C
66
±
2˚C
66
±
2˚C
66
±
2˚C
60
±
2˚C
58
±
2˚C
50
±
2˚C
66
±
2˚C
66
±
2˚C
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
39 min
70 min
Saturation
5 min
54 min
85 min
32 min
41 min
28 min
55 min
55 min
59 min
3 Hr
Saturation
5 min
22 min
Manual
Dry
SPEED DRY
HIGH
NO HEAT
Saturation
5 min
25 min
3 Hr
66
±
2˚C
ADJUSTABLE
ADJUSTABLE
NORMAL
ADJUSTABLE
NORMAL
ADJUSTABLE
NORMAL
ADJUSTABLE
NORMAL
ADJUSTABLE
NORMAL
ADJUSTABLE
OFF
OFF
OFF
VERY
OFF
OFF
AIR DRY
Saturation
30 min
OFF
50
±
2˚C
60
±
2˚C
NORMAL
ADJUSTABLE
When checking components, turn the power off and discharge voltage.
COMPONENT TESTING INFORMATION
5
!
CAUTION
Component
Test Procedure
Check result
Remark
1. Thermal cut off
•
Check Top Marking:
N140
Measure resistance of terminal
to terminal
Open at 284 ± 41°F
(140 ± 5°C)
Auto reset -31°F (-35°C)
Same shape as outlet thermostat.
If thermal fuse is open must
be replaced
Resistance value
∞
Continuity (250°F
˨
) < 1
Ω
•
Heater case-
Safety
•
Electric type
2. Hi limit Thermostat
(Auto reset)
Measure resistance of terminal
to terminal
Open at 257 ± 9°F
(125 ± 5°C)
Close at 221 ± 9°F
(94 ± 7°C)
Resistance value
∞
Resistance value < 5
Ω
•
Heater case -
Hi limit
•
Electric type
3. Outlet Thermostat
( Auto reset)
•
Check Top Marking:
N85
Measure resistance of terminal
to terminal
Open at 185 ± 41°F
(85 ± 5°C)
Close at 167 ± 41°F
(75 ± 5°C)
Same shape as thermal cut off.
Resistance value
∞
Resistance value < 5
Ω
•
Blow housing -
Safety
•
Electric type
4. LED Lamp
Schematic:
If the lamp is turned on
by connecting is normal.
It is not
measured by
multimeter
because V is
3.2V
th
6. Idler switch
Measure resistance of the
following terminal:
COM - NC
1. Lever open
Resistance value < 1
Ω
2. Lever push (close)
Resistance value
∞
5. Door switch
Measure resistance of the
following terminal
1) Door open
Terminal: COM - NC (1-3)
Terminal: COM - NO (1-2)
2) Door closed
Terminal: COM - NC (1-3)
Terminal: COM - NO (1-2)
Resistance value < 1
Ω
Resistance value
∞
Resistance value
∞
Resistance value < 1
Ω
19
4
DRYER CYCLE PROCESS
Summary of Contents for DLEX8000
Page 11: ...11 Connecting electric dryers ...
Page 15: ...15 Connecting Electric Dryers cont USA only ...
Page 21: ...21 7 WIRING DIAGRAM 23 7 WIRING DIAGRAM ...
Page 52: ...52 13 EXPLODED VIEW 54 A211 A210 A120 A110 A130 F211 F215 13 EXPLODED VIEW ...
Page 53: ...53 55 K503 K508 K501 A090 K507 K505 K502 A160 A170 K504 K506 A161 A172 A171 A350 ...