8
a.
3-wire receptacle (NEMA type 10-30R)
b.
3-wire plug
c.
Neutral prong
d.
Spade terminals with up turned ends
e.
3/4 in. (1.9 cm) UL approved strain relief
f.
Ring terminals
g.
Neutral (white or center wire)
a.
External ground connector
b.
Neutral grounding wire (white)
c.
Center silver-colored terminal block screw
d.
Neutral wire (white or center wire)
e.
3/4 in. (1.9 cm) UL-listed strain relief
1. Loosen or remove center terminal block screw.
2. Connect neutral wire (white or center wire) of
power supply cord to the center, silver colored
terminal screw of the terminal block. Tighten
screw.
3. Connect the other wires to outer terminal block
screws. Tighten screws.
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of
dryer rear panel. Secure cover with hold-down
screw.
e
a
d
b
c
d
g
f
a
lf your local codes or ordinances permit the
connection of a frame-grounding conductor to the
neutral wire, use these instructions. If your local
codes or ordinances do not allow the connection of
a frame-grounding conductor to the neutral wire,
use the instructions under
Section 3: Optional
3-wire connection.
Option 1: 3-Wire Connection with
a Power Supply Cord
Summary of Contents for D5988B
Page 2: ...Feb 2004 PRINTED IN KOREA P No 3828EL3005A ...
Page 6: ...5 FEATURES AND BENEFITS 2 DLE5977W DLG5988W DLE5977B DLG5988B DLE3777W DLG3788W ...
Page 19: ...18 ELECTRIC DRYER WIRING DIAGRAM WIRING DIAGRAM 8 GAS DRYER WIRING DIAGRAM ...
Page 37: ...36 EXPLODED VIEW 12 12 1 Control Panel Plate Assembly A130 A110 A120 A210 ...
Page 38: ...37 12 2 Cabinet Door Assembly A320 A600 A310 A700 A390 A800 A330 A500 A460 A410 A400 ...