9
a.
4-wire receptable (NEMA type 14-30R)
b.
4-pront plug
c.
Ground prong
d.
Neutral Prong
e.
Spade terminals with upturned ends
f.
3/4 in. (1.9 cm) UL approved strain relief
g.
Ring terminals
a.
External ground connector - Dotted line
shows position of NEUTRAL ground wire
before being moved to center terminal block
screw
b.
Center silver-colored terminal block screw
c.
White wire of harness
1. Remove center terminal block screw.
2. Remove appliance neutral ground wire (white)
from external ground connector screw. Fasten it
under the center, silver colored terminal block
screw.
3. Connect ground wire (green or bare) of power
supply cable to external ground conductor screw.
Tighten screw.
4. Connect neutral wire (white or center wire) of
power supply cord to the center, silver colored
terminal screw of the terminal block.
a
b
c
a.
External ground connector
b.
Green or bare copper wire of power supply cord
c.
3/4 in. (1.9 cm) UL-listed strain relief
d.
Center silver-colored terminal block screw
e.
Neutral grounding wire (white)
f.
Neutral wire (white)
5. Connect the other wires to outer terminal block
screws. Tighten screws.
6. Tighten strain relief screws.
7. Insert tab of terminal block cover into slot of
dryer rear panel. Secure cover with hold-down
screw.
f
a
b
e
d
c
• lf your local codes or ordinances do not allow the
use of a 3 wire connection, or you are installing
your dryer in a mobile home, you must use a 4-
wire connection.
Option 2: 4-wire connection with a
Power supply cord.
Summary of Contents for D5988B
Page 2: ...Feb 2004 PRINTED IN KOREA P No 3828EL3005A ...
Page 6: ...5 FEATURES AND BENEFITS 2 DLE5977W DLG5988W DLE5977B DLG5988B DLE3777W DLG3788W ...
Page 19: ...18 ELECTRIC DRYER WIRING DIAGRAM WIRING DIAGRAM 8 GAS DRYER WIRING DIAGRAM ...
Page 37: ...36 EXPLODED VIEW 12 12 1 Control Panel Plate Assembly A130 A110 A120 A210 ...
Page 38: ...37 12 2 Cabinet Door Assembly A320 A600 A310 A700 A390 A800 A330 A500 A460 A410 A400 ...