20
Test 1
120VAC Electrical supply
Caution
Trouble Symptom
Measurement Condition
When measuring power, be sure to wear insulated gloves, to and avoid an
electric shock.
No power was applied to Controller. (LED, Display off)
With Dryer Power On; Connector linked to Controller.
Check the outlet, is the voltage
110V ~ 125V AC?
YES
NO
• Check the fuse
or circuit breaker.
Check if the voltage measured between
Connector “RD3-
” (Black) linked to the
Controller and “WH3-
”(White) is
110V ~ 125V?
YES
NO
• Check if Power
Cord is properly
connected.
• Reconnect the
controller.
Replace controIler.
Check if the Controller wire is
disconnected.
Check if Terminal Block and Power Cord
are connected (Check Plug ).
- Does Power Cord N( Natural) line match
to Terminal Center N(Natural) line?
YES
NO
L (Black)
L (Led)
N(White)
Summary of Contents for D5988B
Page 2: ...Feb 2004 PRINTED IN KOREA P No 3828EL3005A ...
Page 6: ...5 FEATURES AND BENEFITS 2 DLE5977W DLG5988W DLE5977B DLG5988B DLE3777W DLG3788W ...
Page 19: ...18 ELECTRIC DRYER WIRING DIAGRAM WIRING DIAGRAM 8 GAS DRYER WIRING DIAGRAM ...
Page 37: ...36 EXPLODED VIEW 12 12 1 Control Panel Plate Assembly A130 A110 A120 A210 ...
Page 38: ...37 12 2 Cabinet Door Assembly A320 A600 A310 A700 A390 A800 A330 A500 A460 A410 A400 ...