26
Test 7
GAS Valve test - Gas Type
Caution
Trouble Symptom
Measurement Condition
When measuring power, be sure to wear insulated gloves, to avoid electric shock.
While operating, Heating will not work.
Drying time takes longer.
With dryer power on
• Harness check
• Controller change
When measuring terminal resistance on “Valve 1”,
“Valve 2”, Value is more than1.5 ~ 2.5kΩ?
(Measure after Off )
NO
YES
• Change Valve
• Check thermostat
Hi limit Safety
Igniter operates?
(after 1 min, Igniter becomes reddish)
YES
NO
• Check Igniter &
Frame detect
When measuring Valve 2 voltage, Value is more
than AC 90V? (10 sec after Igniter off)
NO
YES
• Check Gas
connection or
Gas supply
When measuring Valve 1 voltage,
More than AC 90V?
YES
NO
Power On & Start (Normal Cycle)
NO
Igniter
Valve 2
Valve 1
Summary of Contents for D5988B
Page 2: ...Feb 2004 PRINTED IN KOREA P No 3828EL3005A ...
Page 6: ...5 FEATURES AND BENEFITS 2 DLE5977W DLG5988W DLE5977B DLG5988B DLE3777W DLG3788W ...
Page 19: ...18 ELECTRIC DRYER WIRING DIAGRAM WIRING DIAGRAM 8 GAS DRYER WIRING DIAGRAM ...
Page 37: ...36 EXPLODED VIEW 12 12 1 Control Panel Plate Assembly A130 A110 A120 A210 ...
Page 38: ...37 12 2 Cabinet Door Assembly A320 A600 A310 A700 A390 A800 A330 A500 A460 A410 A400 ...