4. TROUBLE SHOOTING
- 75 -
Checking Flow
SETTING : Connect PIF to the phone, and Power on. Enter the engineering mode, and set
"Melody on" at Buzzer of BB test menu.
START
Voltage across C409
> 3.3 V?
Replace U102
( ABB LDO)
No
Yes
The voltage
of R075 is ~2.8V
Yes
Check the state of contact of
dual mode speaker
Speaker
Working!!
Yes
Check the signal level of
C406,C407
No
Replace U401
No
Replace U402
Check the soldering of
U402
No
Yes
Re-soldering
U402
No
Replace speaker