4. TROUBLE SHOOTING
- 79 -
START
Is the voltage at pin 6
of Q202 near 0V?
Check the soldering of CN301
Resol der CN201.
Check the soldering of
vibrator at LCD module
Resol der vi brator.
VIBRAT OR WILL
WORK PROPERLY.
Repl ace Vibrator.
Check the soldering of R223.
Resol der R223.
Repl ace Q202.
NO
YES
NO
NO
NO
YES
YES
Checking Flow
SETTING : After Initialize Agilent 8960, Test in EGSM, Connect PIF to the phone, and Power
on. Enter The engineering mode, and set ‘Vibrator on’ at Vibration of BB test
menu.